Pepperl-Fuchs EGT-101 

Isolated Repeaters

2-channel - ATEX approval - Inputs EEx ia IIC - DC 24 V supply voltage - Ex-parameters of the intrinsically safe circuits: U0 = 26 V, I0 = 93 Ma - Input: 0 mA ... 20 mA Output: 0 mA ... 20 mA
(input/output  options  see  table  on page  4) - Current  output: load: max. 1 kÙ Voltage  output load: ≥ 50 kÙ - Test  jacks - LED  for  output  current  control   

Katalog
Sertifika
PDF

Pepperl-Fuchs EGT-105 

Isolated Repeaters

The EGT-105 repeater  transfers an electrical unit signal from the safe area to a hazardous area. A conversion of a current signal into a voltage signal or vice versa, is possible. The result is that the device can be delivered with different options.         

Katalog PDF
Sertifika PDF

Pepperl-Fuchs EG2-R 

Isolated switch amplifiers

The transformer isolated amplifier transmits digital signals from the hazardous area. Sensors per DIN 19234 (NAMUR) or mechanical contacts may serve as alarms. The control circuit can be monitored for lead breakage monitoring (LB).                                                                   

Katalog PDF
Sertifika PDF

Pepperl-Fuchs EG4-R 

Isolated switch amplifiers

 

The transformer isolated amplifier transmits digital signals from the hazardous area. Sensors per DIN 19234 (NAMUR) or mechanical contacts can serve as alarms. The control circuit can be monitored through lead breakage monitoring (LB).                 

Katalog PDF
Sertifika PDF

Pepperl-Fuchs EGA-041-3

Solenoid drivers

The EGA-041 has a logic input with which the field device is controllable. Voltage signals
in the range of DC 15 V ... 30 V are accepted as logic-1. Logic-0 must lie in the DC 0 V ... 5 V range. The current consumption of the logic input is about 5 mA.          

     
Katalog PDF
Sertifika PDF

Pepperl-Fuchs EG2-M2-DW

Rotational speed controller

Output relay operating mode b16 (chan. 1), b18 (chan. 2) Logic-1: Output relay is energised and de-energised only when the set frequency is exceeded. Logic-0: Output relay is de-energised and energises only when the set frequency is exceeded.       

Katalog PDF
Sertifika PDF

Pepperl-Fuchs EG1-M4-FSU 

Frequency converter

The frequency / current converter transforms the input frequency into an impressed DC current. It is designed for connection with a sensor per NAMUR. The unit can be controlled with a 24 V DC voltage signal via logic input d18. A load of 650 Ohm is allowed at the analog output.          

Katalog PDF
Sertifika PDF

Pepperl-Fuchs EGA-041-3

Solenoid drivers

The EGA-041 has a logic input with which the field device is controllable. Voltage signals
in the range of DC 15 V ... 30 V are accepted as logic-1. Logic-0 must lie in the DC 0 V ... 5 V range. The current consumption of the logic input is about 5 mA.      

     
Katalog PDF
Sertifika PDF

EKSH-03-T / ED2-SH-EX2.T

Isolated Amplifier (Fail-Safe)

This device meets the safety requirements for the transistor equipment of furnace systems. The transformer isolated amplifier is fail safe. This means that in a fault condition, for example short circuit or component failure, the unit shuts down. This is accomplished by means of dynamic signal transmission channels.                        

Katalog PDF
Sertifika PDF
EKSH-03-T / ED2-SH-EX1.R1
Isolated Amplifier (Fail-Safe)

The transformer isolated amplifier is fail safe. This means that in a fault condition, for example short circuit or component failure, the unit shuts down. This is accomplished by means of dynamic signal transmission channels. When a fault occurs, the oscillation required for a Logic-1 signal breaks, forcing the output into an inactive state.            

Katalog PDF
Sertifika PDF
Pepperl-Fuchs 2RSH / ED2-RSH-2
Relay Card

Multiple relay cards can be connected to the intrinsic safety transformer isolated amplifier with transistor output from Pepperl+Fuchs (see application on page 95). With this, interconnected safety circuits can be realized.                                                                  

Katalog PDF
Sertifika PDF
a
Pepperl-Fuchs ED2-UT-Ex2 / EGC-120
Converter

The ED2-UT-Ex2 is designed for the connection of Pt100 and Ni100 (2-, 3- or 4-wire sensors) resistance temperature sensors as well as model B, E, J, K, L, N, R, S or T thermocouples. A temperature linear, current signal of 0/4mA ... 20mA is available at the output.

Katalog PDF
Sertifika PDF
a
Pepperl-Fuchs EG2-R  
Transformer Isolated Amğlifier

These devices meet the safety requirments for the electrical equipment of firing systems.
It is constructed in accordance with DIN prEN 50 156-1 or DIN VDE 0116 and is suited for requirement classes 1 ... 3 per DIN v 19 250. The conformity of the device has been tested and approved by TÜV.

Katalog PDF
Sertifika PDF
a
STOKTA BULUNAN ÖZEL KARTLAR

MUS 80 TV 80

Eckard

Transmitter Power Supply Unit Type:5 926 184

II 949

Eckard

DC Voltage İsolating ModuleType:5 949 624

F 3209

HİMA

4 Channel Barier PTB Nr.Ex-79/2 010 x

PMX 672 Z

E&HAUSER

Level Control Ex Zone 2

HTA 470 Z

E&HAUSER

Two Point Level Control Contacter

FTM 480 Z

E&HAUSER

Alarm Level Monitor 100V 50/60HZ

A SSY NO 800-09-9316-2

QUANTUM

Power Req 5/12V-8W

278-4520-00

Doric Instrum.

Power Supply 278

594591 P/N-20669-003

Archive Corp.

LR 56637

907C00654

NUDAQ

ADL-ACL-6126 A+2 831

PCL 816/N8E00266202

Advantech

Modular High Resulution DAS Card

01B005-01

Micro Electr.

Controller Serial:01030979 Rev.Nr.03.01.03

HP-IB 82335

HP

82335-60001-3707-92-199835-00164

FCC:H9MSUN6307

CF

E119801 94V0 04V0

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 